<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>IAAC Blog &#187; S1. Ecotect</title>
	<atom:link href="http://legacy.iaacblog.com/blog/tag/s1-ecotect/feed/" rel="self" type="application/rss+xml" />
	<link>http://legacy.iaacblog.com</link>
	<description>Everyday life at the Institute for advanced architecture of Catalonia</description>
	<lastBuildDate>Wed, 07 Oct 2015 10:24:58 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	
		<item>
		<title>Ecotect Analyse for a house</title>
		<link>http://legacy.iaacblog.com/blog/2010/ecotect-analyse-for-a-house/</link>
		<comments>http://legacy.iaacblog.com/blog/2010/ecotect-analyse-for-a-house/#comments</comments>
		<pubDate>Fri, 07 May 2010 18:10:26 +0000</pubDate>
		<dc:creator></dc:creator>
				<category><![CDATA[S5. Environmental Performance Modelling]]></category>
		<category><![CDATA[Bulgaria]]></category>
		<category><![CDATA[S1. Ecotect]]></category>
		<category><![CDATA[Varna]]></category>

		<guid isPermaLink="false">http://legacy.iaacblog.com/?p=1887</guid>
		<description><![CDATA[Hristo Topchiev Board 1 PRESS here for: Panels in pdf format Board 2]]></description>
				<content:encoded><![CDATA[<p>Hristo Topchiev</p>
<p>Board 1</p>
<p><a href="http://legacy.iaacblog.com/wp-content/uploads/2010/05/board1_1.jpg"><img src="http://legacy.iaacblog.com/wp-content/uploads/2010/05/board1-Copy-21.jpg" alt="" width="640" height="448" /></a></p>
<p>PRESS here for: <a title="Press here for pdf files" href="http://legacy.iaacblog.com/2010/05/ecotect-analyse-for-a-house/panels-hristo-topchiev_a2/">Panels in pdf format</a></p>
<p>Board 2</p>
<p><a href="http://legacy.iaacblog.com/wp-content/uploads/2010/05/board21.jpg"><img class="alignleft size-full wp-image-1901" src="http://legacy.iaacblog.com/wp-content/uploads/2010/05/board2-Copy-21.jpg" alt="" width="640" height="448" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://legacy.iaacblog.com/blog/2010/ecotect-analyse-for-a-house/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Final Assignment</title>
		<link>http://legacy.iaacblog.com/blog/2010/final-assignment/</link>
		<comments>http://legacy.iaacblog.com/blog/2010/final-assignment/#comments</comments>
		<pubDate>Fri, 07 May 2010 16:50:32 +0000</pubDate>
		<dc:creator></dc:creator>
				<category><![CDATA[S5. Environmental Performance Modelling]]></category>
		<category><![CDATA[S1. Ecotect]]></category>

		<guid isPermaLink="false">http://legacy.iaacblog.com/?p=1825</guid>
		<description><![CDATA[Renata Nogueira Download PDF here]]></description>
				<content:encoded><![CDATA[<p>Renata Nogueira</p>
<p><a href="http://legacy.iaacblog.com/wp-content/uploads/2010/05/p1.jpg"><img class="alignnone size-large wp-image-1823" src="http://legacy.iaacblog.com/wp-content/uploads/2010/05/p1-600x423.jpg" alt="" width="600" height="423" /></a></p>
<p><a rel="attachment wp-att-1824" href="http://legacy.iaacblog.com/2010/05/final-assignment/p2/"><img class="alignnone size-large wp-image-1824" src="http://legacy.iaacblog.com/wp-content/uploads/2010/05/p2-600x476.jpg" alt="" width="600" height="476" /></a></p>
<p><a href="http://legacy.iaacblog.com/wp-content/uploads/2010/05/RenataNogueira_Ecotect.pdf">Download PDF here</a></p>
]]></content:encoded>
			<wfw:commentRss>http://legacy.iaacblog.com/blog/2010/final-assignment/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Environmental Performance Modelling &amp; Visualization</title>
		<link>http://legacy.iaacblog.com/blog/2010/mumbay-port-analysis/</link>
		<comments>http://legacy.iaacblog.com/blog/2010/mumbay-port-analysis/#comments</comments>
		<pubDate>Fri, 07 May 2010 03:53:22 +0000</pubDate>
		<dc:creator></dc:creator>
				<category><![CDATA[S5. Environmental Performance Modelling]]></category>
		<category><![CDATA[S1. Ecotect]]></category>
		<category><![CDATA[solar radiation]]></category>

		<guid isPermaLink="false">http://legacy.iaacblog.com/?p=1713</guid>
		<description><![CDATA[]]></description>
				<content:encoded><![CDATA[<p><a rel="attachment wp-att-1717" href="http://legacy.iaacblog.com/2010/05/mumbay-port-analysis/ecotect-1/"><img class="alignnone size-large wp-image-1717" src="http://legacy.iaacblog.com/wp-content/uploads/2010/05/Ecotect-1-600x848.jpg" alt="" width="600" height="848" /></a></p>
<p><a rel="attachment wp-att-1922" href="http://legacy.iaacblog.com/2010/05/mumbay-port-analysis/ecotect-2/"><img class="alignnone size-large wp-image-1922" src="http://legacy.iaacblog.com/wp-content/uploads/2010/05/Ecotect-2-600x848.jpg" alt="" width="600" height="848" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://legacy.iaacblog.com/blog/2010/mumbay-port-analysis/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Environmental Performance Modelling and Visualization</title>
		<link>http://legacy.iaacblog.com/blog/2010/environmental-performance-modelling-and-visualization/</link>
		<comments>http://legacy.iaacblog.com/blog/2010/environmental-performance-modelling-and-visualization/#comments</comments>
		<pubDate>Fri, 07 May 2010 00:33:59 +0000</pubDate>
		<dc:creator></dc:creator>
				<category><![CDATA[S5. Environmental Performance Modelling]]></category>
		<category><![CDATA[environmental]]></category>
		<category><![CDATA[S1. Ecotect]]></category>
		<category><![CDATA[site analysis]]></category>

		<guid isPermaLink="false">http://legacy.iaacblog.com/?p=1690</guid>
		<description><![CDATA[site analysis + proposal for a building in mexico city: environmental conditions as design drivers.]]></description>
				<content:encoded><![CDATA[<p>site analysis + proposal for a building in mexico city: environmental conditions as design drivers.</p>
<p><img class="aligncenter size-large wp-image-1688" src="http://legacy.iaacblog.com/wp-content/uploads/2010/05/Final-Board-01-600x396.jpg" alt="" width="600" height="396" /></p>
<p><a rel="attachment wp-att-1689" href="http://legacy.iaacblog.com/2010/05/environmental-performance-modelling-and-visualization/final-board-02/"><img class="aligncenter size-large wp-image-1689" src="http://legacy.iaacblog.com/wp-content/uploads/2010/05/Final-Board-02-600x394.jpg" alt="" width="600" height="394" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://legacy.iaacblog.com/blog/2010/environmental-performance-modelling-and-visualization/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>house in greece environmental performance study</title>
		<link>http://legacy.iaacblog.com/blog/2010/house-in-greece-environmental-performance-study/</link>
		<comments>http://legacy.iaacblog.com/blog/2010/house-in-greece-environmental-performance-study/#comments</comments>
		<pubDate>Fri, 16 Apr 2010 21:53:14 +0000</pubDate>
		<dc:creator></dc:creator>
				<category><![CDATA[S5. Environmental Performance Modelling]]></category>
		<category><![CDATA[environmental]]></category>
		<category><![CDATA[S1. Ecotect]]></category>
		<category><![CDATA[sustainable design]]></category>

		<guid isPermaLink="false">http://legacy.iaacblog.com/?p=797</guid>
		<description><![CDATA[For the purpose of this seminar I am going to study the environmental performance for a house of 140 m2 I designed which is currently being under construction. During the design of the house I used the theoretical backgound of sustainable design.In this assignment I am  going to use Ecotect in order to 1) assess the so [...]]]></description>
				<content:encoded><![CDATA[<p>For the purpose of this seminar I am going to study the environmental performance for a house of 140  m2 I designed which is currently being under construction. During the design of the house I used the theoretical backgound of sustainable design.In this assignment I am  going to use Ecotect in order to 1) assess the so far design choices made 2) optimise the environmental performanceof the design through moderate changes in shading elements types and materials.</p>
<p>One of the most important decisions in design was the house’s orientation. In order to maximize the solar gains in winter and minimise them during summer the houses largest percentage of openings were orientated towards the south.</p>
<p><a href="http://legacy.iaacblog.com/wp-content/uploads/2010/04/summer-cummulative-solar-incidence-300x2261.jpg"><img class="aligncenter size-full wp-image-798" src="http://legacy.iaacblog.com/wp-content/uploads/2010/04/summer-cummulative-solar-incidence-300x2261.jpg" alt="" width="300" height="226" /></a></p>
<p>summer incident solar radiation</p>
<p><a href="http://legacy.iaacblog.com/wp-content/uploads/2010/04/winter-cummulative-solar-gains-300x2261.jpg"><img class="aligncenter size-full wp-image-799" src="http://legacy.iaacblog.com/wp-content/uploads/2010/04/winter-cummulative-solar-gains-300x2261.jpg" alt="" width="300" height="226" /></a></p>
<p>winter incident solar radiation</p>
<p>In a diagramatical comparison of the total incident solar radiation expressed in cumulative values we see in the summer the house gets less exposed to incident solar radiation than in the winter due to its orientation.</p>
<p>By conducting thermal analysis on the actual orientation of the house we get  total number of 17296932 Wh for heating and cooling gains on a fully airconditioning model.</p>
<p><a href="http://legacy.iaacblog.com/wp-content/uploads/2010/04/monthly-heating-coolingloads-300x1231.jpg"><img class="aligncenter size-full wp-image-800" src="http://legacy.iaacblog.com/wp-content/uploads/2010/04/monthly-heating-coolingloads-300x1231.jpg" alt="" width="300" height="123" /></a></p>
<p>On a hypothetical 37 deg rotation of the North  (which would place the house orthogonally to the site) the same analysis we get the sum of  16247432 Wh</p>
<p>Although, the same analysis on an only heating model proves that the thermal confort is covered by a percentage of that ranges from 86.2% to 89.6% . The conclusion could be that the house could function without cooling systems supporting it.</p>
<p><a href="http://legacy.iaacblog.com/wp-content/uploads/2010/04/annual-temp-fully-aircond-300x1231.jpg"><img class="aligncenter size-full wp-image-801" src="http://legacy.iaacblog.com/wp-content/uploads/2010/04/annual-temp-fully-aircond-300x1231.jpg" alt="" width="300" height="123" /></a></p>
<p>annual distribution of temeratures in fully air-conditioned model (zone6)</p>
<p>On a hypothetical 37 deg rotation of the North  (which would place the house orthogonally to the site) the same analysis proves that the percentage of thermal confort drops to 82.5%-87.9% while the thermal analysis on the actual orientation of the house provides a number of 17296932 Wh for heating and cooling gains on a fully air-conditioning model.</p>
<p>For the master bedroom (zone 5) two different types of shading were tested through the software: vertical  and rotated louvres.</p>
<p><a href="http://legacy.iaacblog.com/wp-content/uploads/2010/04/30-iou-str1.jpg"><img class="aligncenter size-full wp-image-802" src="http://legacy.iaacblog.com/wp-content/uploads/2010/04/30-iou-str1.jpg" alt="" /></a></p>
<p><a href="http://legacy.iaacblog.com/wp-content/uploads/2010/04/dir-sol-gains-rot-300x1231.jpg"><img class="aligncenter size-full wp-image-803" src="http://legacy.iaacblog.com/wp-content/uploads/2010/04/dir-sol-gains-rot-300x1231.jpg" alt="" width="300" height="123" /></a></p>
<p>VERTICAL LOUVRES<br />
HOURLY TEMPERATURES – Saturday 30th June (181)</p>
<p>Zone:  Zone 5<br />
Avg. Temperature:  26.1 C  (Ground 17.9 C)<br />
Total Surface Area:  86.400  m2 (540.0% flr area).<br />
Total Exposed Area:  56.800 m2  (355.0% flr area).<br />
Total South Window:  0.000  m2 (0.0% flr area).<br />
Total Window Area:  3.340 m2  (20.9% flr area).<br />
Total Conductance (AU):  84 W/°K<br />
Total Admittance (AY):  322 W/°K<br />
Response Factor:  3.57</p>
<p><a href="http://legacy.iaacblog.com/wp-content/uploads/2010/04/30-iou-rot-1.jpg"><img class="aligncenter size-full wp-image-804" src="http://legacy.iaacblog.com/wp-content/uploads/2010/04/30-iou-rot-1.jpg" alt="" /></a></p>
<p><a href="http://legacy.iaacblog.com/wp-content/uploads/2010/04/dir-sol-gains-xwris-300x1231.jpg"><img class="aligncenter size-full wp-image-805" src="http://legacy.iaacblog.com/wp-content/uploads/2010/04/dir-sol-gains-xwris-300x1231.jpg" alt="" width="300" height="123" /></a></p>
<p>ROTATED LOUVRES<br />
HOURLY TEMPERATURES – Saturday 30th June (181)</p>
<p>Zone:  Zone 5<br />
Avg. Temperature:  26.1 C  (Ground 17.9 C)<br />
Total Surface Area:  86.400  m2 (540.0% flr area).<br />
Total Exposed Area:  56.469 m2  (352.9% flr area).<br />
Total South Window:  0.000  m2 (0.0% flr area).<br />
Total Window Area:  3.340 m2  (20.9% flr area).<br />
Total Conductance (AU):  83 W/°K<br />
Total Admittance (AY):  321 W/°K<br />
Response Factor:  3.58</p>
<p>From the comparison in these two cases we see a minimal increase on the responce factor and a 0.331  m2 decrease on the exposed area. Therefore the impact of the orientation of the louvres is minimal on a horisontal  placement.</p>