Monthly Archives: June 2013

Actuation tests

Testing the actuation with high voltage electricity and material properties of the membranes at the same time. Membranes appear to be very sensitive to voltage above 4kV. They tend to damage quite easily. Actuation usually starts around 1.3 / 1.5 kV. Discharging capacitor and converter is done manually, via bleeder resistors board. Capacitor should store [...]

Posted in electronics, fabrication, geometry, Thesis | Comments closed

Polymer actuation test 1.0

Testing the actuation of the polymer film. Materials and electronics: VHB polymer film, conductive graphite powder, acrylic glass, high voltage converter, variable power supply, cables.

Posted in electronics, fabrication, geometry, Thesis | Comments closed

Electroactive polymer membrane test

Testing the elasticity of VHB polymer film membranes attached to the planar surface. This method could be applied to the system of polymer actuators inside the final object prototype.  

Posted in fabrication, geometry, Thesis | Comments closed